{"title":"Gamewell-FCI Smoke Detectors","description":"\u003cp\u003e\u003cstrong\u003eGamewell Fci Smoke Detectors\u003c\/strong\u003e for commercial fire alarm systems.\u003c\/p\u003e\u003cp\u003eGamewell-FCI (Honeywell) builds intelligent addressable fire alarm systems trusted by code officials and AHJs nationwide. The S3 Series (SLP) and FlashScan\/CLIP platforms deliver scalable life safety for buildings of every size.\u003c\/p\u003e\u003cp\u003eThis collection includes \u003cstrong\u003e8+ Gamewell Fci Smoke Detectors\u003c\/strong\u003e. Browse intelligent addressable and conventional smoke detectors from leading fire alarm manufacturers — photoelectric, ionization, multi-criteria, and CO\/smoke combination sensors.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed help confirming compatibility?\u003c\/strong\u003e Contact our technical team before ordering — verify panel\/device family compatibility for your installation.\u003c\/p\u003e","products":[{"product_id":"gamewell-fci-asd-pl3-intelligent-photoelectric-smoke-sensor-white","title":"Gamewell-FCI ASD-PL3 Velociti Addressable Smoke Detector","description":"\u003ch2\u003eThe \u003cstrong\u003eGamewell-FCI ASD-PL3\u003c\/strong\u003e is an intelligent addressable photoelectric smoke detector in the Velociti Series 3 family.\u003c\/h2\u003e\n\u003cp\u003eIt uses a re-engineered optical sensing chamber tuned for the wider combustion-source range required by UL 268 7th Edition, with sensitivity programmable per panel software.\u003c\/p\u003e\n\u003cp\u003eEach detector occupies one address on the loop and reports continuous temperature data back to the panel for selective maintenance and exact device location. Rotary decimal switches set addresses from 01 to 159. Dual bicolor LEDs provide 360 degree visibility (green on poll, red on alarm).\u003c\/p\u003e\n\u003ch2\u003eVelociti Series 3 vs earlier Velociti generations\u003c\/h2\u003e\n\u003cp\u003eThe Series 3 chamber redesign extends sensitivity across more combustion types than the original Velociti and Velociti 2 chambers, while keeping the same address logic and panel integration. ASD-PL3 is the white, Velociti-only variant. For installations still running CLIP-protocol detectors on E3 or S3 panels, use the ASD-PL3-IV ivory variant instead.\u003c\/p\u003e\n\u003ch2\u003eCompatible panels: E3 Series, S3 Series, GWF-7075\u003c\/h2\u003e\n\u003cp\u003eASD-PL3 runs on Velociti protocol. E3 Series and S3 Series panels speak Velociti natively with full feature support. The GWF-7075 supports Velociti but does not handle CLIP, which is not an issue for the white ASD-PL3 but matters when mixing with -IV detectors on the same loop.\u003c\/p\u003e\n\u003ch2\u003eListings and approvals\u003c\/h2\u003e\n\u003cp\u003eUL Listed S2332 under UL 268 7th Edition. FM Approved 3023594. CSFM 7272-1703:0501. MEA FDNY COA-219-02-E Vol. VI. ISO 9001 certified manufacturing.\u003c\/p\u003e\n\u003ch2\u003eBase required, sold separately\u003c\/h2\u003e\n\u003cp\u003eThe detector head ships without a base. Typical pairings are the B501-WHITE 4-inch flangeless base for surface-flush installs, or the B300-6 6-inch flanged base for legacy ceiling boxes. Sounder, isolator, and relay bases from the B200 and B224 series are also compatible (see compatible bases list).\u003c\/p\u003e","brand":"Gamewell-FCI","offers":[{"title":"Default Title","offer_id":50007020470565,"sku":"ASD-PL3","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/7648\/4645\/files\/gamewell-fci-smoke-detectors-default-title-gamewell-fci-asd-pl3-photoelectric-smoke-sensor-white-31962778337504.jpg?v=1771297450"},{"product_id":"gamewell-fci-asd-pl3-iv-addressable-smoke-detector","title":"Gamewell-FCI ASD-PL3-IV Velociti Addressable Smoke Detector","description":"\u003cp\u003eThe \u003cstrong\u003eGamewell-FCI ASD-PL3-IV\u003c\/strong\u003e is the ivory variant of the Velociti Series 3 photoelectric smoke detector. It pairs the re-engineered UL 268 7th Edition optical chamber of the ASD-PL3 with backwards-compatibility for the legacy CLIP protocol, so it can serve as a drop-in replacement on systems that still carry CLIP-protocol detectors on the loop.\u003c\/p\u003e\u003cp\u003eEach detector occupies one address on a Gamewell-FCI loop and reports continuous temperature data back to the panel. Rotary decimal switches set addresses from 01 to 159. Dual bicolor LEDs provide 360 degree visibility (green on poll, red on alarm).\u003c\/p\u003e\u003ch2\u003eDirect replacement for the legacy ASD-PL2F\u003c\/h2\u003e\u003cp\u003eThe ASD-PL2F (Velociti Series 2 photoelectric, CLIP-only) is end-of-life. The ASD-PL3-IV is the correct successor for installations still running CLIP detectors: it speaks both Velociti and CLIP, so it can join an existing CLIP loop without forcing a wholesale loop conversion. Do not substitute the white ASD-PL3 (Velociti-only) on a CLIP loop, protocol mismatch will leave the address unresponsive.\u003c\/p\u003e\u003ch2\u003eCompatible panels: E3 Series, S3 Series, GWF-7075\u003c\/h2\u003e\u003cp\u003eE3 Series and S3 Series panels handle both Velociti and CLIP, so the ASD-PL3-IV fits either protocol mode on those panels. The GWF-7075 supports Velociti only, installing an ASD-PL3-IV there works in Velociti mode but the CLIP fallback never activates on that panel.\u003c\/p\u003e\u003ch2\u003eWhy ivory instead of white\u003c\/h2\u003e\u003cp\u003eIvory is the legacy finish for older Gamewell-FCI \/ FCI installations. It exists primarily so retrofit jobs do not leave a single white detector in a ceiling full of ivory ones. Specs are identical to the white ASD-PL3, sensitivity, mounting, base compatibility all match.\u003c\/p\u003e\u003ch2\u003eListings and approvals\u003c\/h2\u003e\u003cp\u003eUL Listed S2332 under UL 268 7th Edition. FM Approved 3023594. CSFM 7272-1703:0501. MEA FDNY COA-219-02-E Vol. VI. ISO 9001 certified manufacturing.\u003c\/p\u003e\u003ch2\u003eBase required, sold separately\u003c\/h2\u003e\u003cp\u003eThe detector head ships without a base. Typical pairings: B501-IV (ivory 4-inch flangeless) for surface flush, B300-6-IV (ivory 6-inch flanged) for legacy ceiling boxes. Ivory bases match the detector finish; white bases also fit but break the ceiling-color match.\u003c\/p\u003e","brand":"Gamewell-FCI","offers":[{"title":"Default Title","offer_id":51722985537829,"sku":"ASD-PL3-IV","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/7648\/4645\/files\/gamewell-fci-smoke-detectors-default-title-gamewell-fci-asd-pl3-iv-addressable-smoke-detector-ivory-35588914151648.jpg?v=1771297412"},{"product_id":"gamewell-fci-mcs-ptir","title":"Gamewell-FCI MCS-PTIR Smoke Detector","description":"\u003cp\u003eThe \u003cstrong\u003eGamewell-FCI MCS-PTIR\u003c\/strong\u003e is an intelligent multi-criteria addressable detector that combines photoelectric, thermal (135°F rate-of-rise), and infrared sensors in one head. Three independent signals cross-reference in panel-side algorithms to reject nuisance triggers, theater smoke, dust kicked up by HVAC, cooking aerosols, while staying sensitive to real fire signatures.\u003c\/p\u003e\u003cp\u003eThe detector reports distinct smoke and heat alarms to the panel, so the system can map different evacuation strategies: local alarm on photoelectric trip, full general evacuation on thermal trip. Single Velociti address per detector. White finish.\u003c\/p\u003e\u003ch2\u003eThree sensors, distinct alarms, when this design wins\u003c\/h2\u003e\u003cp\u003eTheater stages, hotel lobbies, hospital common areas, performance venues, places where nuisance smoke is expected but real fire still needs immediate response. Single-sensor photoelectric detectors trip on theater fog and trigger costly evacuations; thermal-only misses smouldering fires too early. The MCS-PTIR algorithm waits for two of the three sensors to agree before alarming, which sharply reduces false trips without losing time on real fires.\u003c\/p\u003e\u003ch2\u003eAir velocity limit vs MCS-COF3\u003c\/h2\u003e\u003cp\u003eThe MCS-PTIR is rated 0 to 300 ft\/min. For HVAC paths or higher-velocity ceilings (up to 4,000 ft\/min), specify the MCS-COF3, its sensor stack includes a CO cell and the air velocity envelope is wider. Pick by environment first: PTIR for room\/lobby ceilings, COF3 for duct and high-velocity areas requiring CO coverage.\u003c\/p\u003e\u003ch2\u003eCompatible panels and listings\u003c\/h2\u003e\u003cp\u003eGamewell-FCI Velociti SLC panels: E3 Series, S3 Series, GWF-7075. UL Listed S1195 under UL 268 7th Edition and UL 521 (heat). FM Approved. CSFM 7272-1703:0508. ISO 9001 certified.\u003c\/p\u003e","brand":"Gamewell-FCI","offers":[{"title":"Default Title","offer_id":51722988159269,"sku":"MCS-PTIR","price":88.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/7648\/4645\/files\/gamewell-fci-multi-criteria-detectors-default-title-gamewell-fci-mcs-ptir-multi-criteria-photoelectric-35162617676000.webp?v=1771297371"},{"product_id":"gamewell-fci-asd-pl3-bp","title":"Gamewell-FCI ASD-PL3-BP - Pack of 10 ASD-PL3 Units","description":"\u003cp\u003eThe \u003cstrong\u003eGamewell-FCI ASD-PL3-BP\u003c\/strong\u003e is a 10-count bulk pack of the ASD-PL3 Velociti Series 3 photoelectric smoke detector. The packaging is the only difference between the BP and the single-unit ASD-PL3, the detectors inside are identical in spec, listing, and firmware.\u003c\/p\u003e\u003cp\u003eEach detector occupies one address on a Gamewell-FCI Velociti loop. The optical chamber meets UL 268 7th Edition with sensitivity programmable per panel software. Rotary decimal switches set addresses from 01 to 159, and dual bicolor LEDs give 360 degree visibility (green on poll, red on alarm).\u003c\/p\u003e\u003ch2\u003eWhen to specify the bulk pack instead of singles\u003c\/h2\u003e\u003cp\u003eThe bulk pack is sized for new-construction floors or full-system installs where ten or more detectors land in the same loop count. Pricing per unit is lower than the single-pack equivalent, and shipping consolidates into one carton instead of ten. For single-detector retrofits or break-fix replacements, order the regular ASD-PL3 instead.\u003c\/p\u003e\u003ch2\u003eCompatible panels: E3 Series, S3 Series, GWF-7075\u003c\/h2\u003e\u003cp\u003eAll ten detectors run on Velociti protocol. E3 Series and S3 Series panels speak Velociti natively. GWF-7075 supports Velociti but not CLIP, relevant only when mixing this loop with -IV detectors.\u003c\/p\u003e\u003ch2\u003eListings and approvals\u003c\/h2\u003e\u003cp\u003eUL Listed S2332 under UL 268 7th Edition. FM Approved 3023594. CSFM 7272-1703:0501. MEA FDNY COA-219-02-E Vol. VI. ISO 9001 certified manufacturing. Same listings as the single-unit ASD-PL3.\u003c\/p\u003e\u003ch2\u003eBases required, sold separately\u003c\/h2\u003e\u003cp\u003eDetector heads ship without bases. Each detector needs its own base, most installs use B501-WHITE (4-inch flangeless) or B300-6 (6-inch flanged). Order bases in the same count as detectors. Sounder, isolator, and relay bases from the B200 and B224 series are also compatible if the loop design calls for them.\u003c\/p\u003e","brand":"Gamewell-FCI","offers":[{"title":"Default Title","offer_id":51722988355877,"sku":"ASD-PL3-BP","price":590.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/7648\/4645\/files\/gamewell-fci-smoke-detectors-default-title-gamewell-fci-asd-pl3-bp-smoke-detector-pack-of-10-asd-pl3-single-units-33029463736544.jpg?v=1771297363"},{"product_id":"gamewell-fci-asd-ptl3","title":"Gamewell-FCI ASD-PTL3 Smoke Detector","description":"\u003cp\u003eThe \u003cstrong\u003eGamewell-FCI ASD-PTL3\u003c\/strong\u003e combines a Velociti Series 3 photoelectric smoke sensor with a thermal sensor in a single intelligent addressable head. The optical chamber is the same UL 268 7th Edition design used across the Velociti Series 3 line; the thermal element adds a 135°F fixed-temperature trigger and a rate-of-rise detector for fast-developing fires.\u003c\/p\u003e\u003cp\u003eEach detector occupies one address on a Gamewell-FCI Velociti loop. Rotary decimal switches set addresses from 01 to 159. Dual bicolor LEDs provide 360 degree visibility (green on poll, red on alarm). Sensitivity is programmable per detector via the panel software.\u003c\/p\u003e\u003ch2\u003eCombined photoelectric and thermal sensing, when to specify\u003c\/h2\u003e\u003cp\u003eThe thermal element supplements photoelectric detection in environments where smouldering smoke alone is an insufficient indicator, or where fast-developing fires produce heat before significant smoke. Common scenarios: cooking-adjacent spaces, mechanical rooms, industrial process areas. The dual sensor logic remains intelligent, the panel sees photo and thermal data independently per address.\u003c\/p\u003e\u003ch2\u003eThermal element specs\u003c\/h2\u003e\u003cp\u003eFixed-temperature trigger at 135°F (57°C). Rate-of-rise: greater than 15°F per minute (8.3°C\/min). Operating range narrows slightly to 32-100°F (0-38°C) when the thermal element is active.\u003c\/p\u003e\u003ch2\u003eCompatible panels: E3 Series, S3 Series, GWF-7075\u003c\/h2\u003e\u003cp\u003eASD-PTL3 runs on Velociti protocol. E3 Series and S3 Series panels speak Velociti natively. The GWF-7075 supports Velociti but not CLIP, relevant only when mixing this loop with -IV detectors.\u003c\/p\u003e\u003ch2\u003eListings and approvals\u003c\/h2\u003e\u003cp\u003eUL Listed S2332 under UL 268 7th Edition. FM Approved 3023594. CSFM 7272-1703:0501. MEA FDNY COA-219-02-E Vol. VI. ISO 9001 certified manufacturing.\u003c\/p\u003e\u003ch2\u003eBase required, sold separately\u003c\/h2\u003e\u003cp\u003eThe detector head ships without a base. Typical pairings: B501-WHITE (4-inch flangeless) for surface flush, B300-6 (6-inch flanged) for legacy ceiling boxes. Sounder, isolator, and relay bases from the B200 and B224 series are also compatible.\u003c\/p\u003e","brand":"Gamewell-FCI","offers":[{"title":"Default Title","offer_id":51722991075621,"sku":"ASD-PTL3","price":86.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/7648\/4645\/files\/gamewell-fci-thermal-sensor-default-title-gamewell-fci-asd-ptl3-thermal-sensor-34645475786976.jpg?v=1771297311"},{"product_id":"gamewell-fci-mcs-ptir-iv","title":"Gamewell-FCI MCS-PTIR-IV Smoke Detector","description":"\u003cp\u003eThe \u003cstrong\u003eGamewell-FCI MCS-PTIR-IV\u003c\/strong\u003e is the ivory variant of the three-sensor multi-criteria detector. Photoelectric, thermal (135°F rate-of-rise), and infrared sensors share one head and one SLC address. Algorithm-driven cross-sensor logic rejects nuisance triggers while keeping fire response fast.\u003c\/p\u003e\u003cp\u003eThe ivory finish supports CLIP backwards-compatibility on legacy E3 and S3 loops, the detector can drop onto an existing CLIP-protocol loop without forcing a wholesale conversion. Specs are otherwise identical to the white MCS-PTIR. Single Velociti or CLIP address per detector.\u003c\/p\u003e\u003ch2\u003eWhy ivory + CLIP, retrofit-grade detector\u003c\/h2\u003e\u003cp\u003eIvory exists for color-matching retrofits where existing ceiling detectors are ivory. CLIP backwards-compat is the protocol layer that makes the SKU usable on old E3 \/ S3 loops still running ASD-PL2F-vintage CLIP detectors. The combination, color match plus protocol compatibility, is the only way to drop a modern multi-criteria detector into a legacy install without wiring rework.\u003c\/p\u003e\u003ch2\u003eThree sensors, distinct alarms, when this design wins\u003c\/h2\u003e\u003cp\u003eTheater stages, hotel lobbies, hospital common areas, performance venues, places where nuisance smoke is expected but real fire still needs immediate response. The MCS-PTIR-IV algorithm waits for two of three sensors to agree before alarming. The detector also reports distinct smoke and heat events, allowing different evacuation strategies on photo vs thermal trips.\u003c\/p\u003e\u003ch2\u003eAir velocity limit vs MCS-COF3\u003c\/h2\u003e\u003cp\u003eRated 0 to 300 ft\/min. For HVAC paths or higher-velocity ceilings plus CO coverage, specify MCS-COF3 (white) or MCS-COF3-IV (ivory) instead. Pick by environment first.\u003c\/p\u003e\u003ch2\u003eCompatible panels and listings\u003c\/h2\u003e\u003cp\u003eGamewell-FCI Velociti or CLIP SLC panels: E3 Series, S3 Series, GWF-7075 (Velociti only). UL Listed S1195 under UL 268 7th Edition and UL 521. FM Approved. CSFM 7272-1703:0508. ISO 9001 certified.\u003c\/p\u003e","brand":"Gamewell-FCI","offers":[{"title":"Default Title","offer_id":51722991239461,"sku":"MCS-PTIR-IV","price":254.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/7648\/4645\/files\/gamewell-fci-multi-criteria-detectors-default-title-gamewell-fci-mcs-ptir-iv-multi-criteria-photo-thermal-infrared-detector-32030192435424.jpg?v=1771297309"},{"product_id":"gamewell-fci-asd-pl3r","title":"Gamewell-FCI ASD-PL3R Velociti Addressable Smoke Detector","description":"\u003cp\u003eThe \u003cstrong\u003eGamewell-FCI ASD-PL3R\u003c\/strong\u003e is the remote-test variant of the Velociti Series 3 photoelectric detector. It shares the re-engineered UL 268 7th Edition optical chamber and Velociti loop integration of the ASD-PL3, with the added ability to be tested remotely when installed in a duct housing.\u003c\/p\u003e\u003cp\u003eEach detector occupies one address on a Gamewell-FCI Velociti loop and reports continuous temperature data back to the panel. Rotary decimal switches set addresses from 01 to 159. Dual bicolor LEDs provide 360 degree visibility (green on poll, red on alarm).\u003c\/p\u003e\u003ch2\u003eRemote test capability for duct installations\u003c\/h2\u003e\u003cp\u003eThe R in ASD-PL3R stands for remote test. When the detector head sits inside a duct housing on a return-air or supply-air duct, physical access for routine functional testing becomes impractical. The ASD-PL3R accepts a test signal from a remote test station so testing can happen at floor level instead of at the duct.\u003c\/p\u003e\u003ch2\u003eUse with DNR or DNRW duct housing\u003c\/h2\u003e\u003cp\u003eThe ASD-PL3R is the detector head only. Pair it with the Gamewell-FCI DNR (non-relay) or DNRW (non-relay, watertight) duct housing for return-air or supply-air duct monitoring per NFPA 90A and IMC 606. Without the duct housing the remote-test capability has no application, for non-duct installs, use the standard ASD-PL3 instead.\u003c\/p\u003e\u003ch2\u003eCompatible panels: E3 Series, S3 Series, GWF-7075\u003c\/h2\u003e\u003cp\u003eASD-PL3R runs on Velociti protocol. E3 Series and S3 Series panels speak Velociti natively with full feature support. GWF-7075 supports Velociti but not CLIP, relevant only when mixing this loop with -IV detectors.\u003c\/p\u003e\u003ch2\u003eListings and approvals\u003c\/h2\u003e\u003cp\u003eUL Listed S2332 under UL 268 7th Edition. FM Approved 3023594. CSFM 7272-1703:0501. MEA FDNY COA-219-02-E Vol. VI. ISO 9001 certified manufacturing.\u003c\/p\u003e\u003ch2\u003eOperating environment expanded for duct\u003c\/h2\u003e\u003cp\u003eWhen installed inside a DNR\/DNRW duct housing, the operating temperature range expands from the standard 32-122°F up to -4°F to 158°F (-20°C to 70°C). Air velocity tolerance: 0 to 4,000 ft\/min. Humidity: 10-93% non-condensing.\u003c\/p\u003e","brand":"Gamewell-FCI","offers":[{"title":"Default Title","offer_id":51722994123045,"sku":"ASD-PL3R","price":73.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/7648\/4645\/files\/gamewell-fci-smoke-detectors-default-title-gamewell-fci-asd-pl3r-photoelectric-smoke-sensor-remote-test-31998361370848.jpg?v=1771297272"},{"product_id":"gamewell-fci-asd-pl2f","title":"Gamewell-FCI ASD-PL2F Velociti Addressable Smoke Detector","description":"\u003cp\u003eThe \u003cstrong\u003eGamewell-FCI ASD-PL2F\u003c\/strong\u003e is the Velociti Series 2 intelligent addressable photoelectric smoke detector. It is a service-only part for existing Series 2 \/ CLIP-protocol installations. For new construction and full retrofits, the correct current SKU is the ASD-PL3-IV, see the cross-reference section below.\u003c\/p\u003e\u003cp\u003eEach detector occupies one address on a Gamewell-FCI loop and reports continuous temperature data back to the panel. Rotary decimal switches set addresses from 01 to 159. Sensitivity is programmable via panel software.\u003c\/p\u003e\u003ch2\u003eWhy this is a service-only part\u003c\/h2\u003e\u003cp\u003eThe Series 3 family (ASD-PL3 and ASD-PL3-IV) supersedes Series 2 with a redesigned optical chamber that meets UL 268 7th Edition. The ASD-PL2F remains in catalog so that integrators servicing existing Velociti Series 2 installations can keep matching detector models on the same loop, a requirement on many AHJ-inspected jobs. New installs and full retrofits should specify ASD-PL3 (Velociti only) or ASD-PL3-IV (Velociti + CLIP) instead.\u003c\/p\u003e\u003ch2\u003eReplacement path: ASD-PL3-IV, not ASD-PL3\u003c\/h2\u003e\u003cp\u003eBecause the ASD-PL2F runs primarily on CLIP-compatible Velociti panels, the only valid direct replacement is the \u003cstrong\u003eASD-PL3-IV\u003c\/strong\u003e, which retains CLIP backwards-compatibility. The white ASD-PL3 is Velociti-only and will not address on a CLIP loop, substituting it leads to an unresponsive address. This protocol rule is hard.\u003c\/p\u003e\u003ch2\u003eCompatible panels (legacy list)\u003c\/h2\u003e\u003cp\u003eGamewell-FCI E3 Series, S3 Series, 7100 Series, 7075 Series, and IdentiFlex 602 (with Velociti\/CLIP loop card). See Compatibility Addendum P\/N 9000-0427-L8 for the complete list.\u003c\/p\u003e\u003ch2\u003eListings and approvals (per current 9020-0617 rev K)\u003c\/h2\u003e\u003cp\u003eUL Listed S2332 under UL 268. FM Approved 3023594. CSFM 7272-1703:0501. MEA FDNY 219-02-E Vol. VI. ISO 9001 certified manufacturing.\u003c\/p\u003e\u003ch2\u003eBase required, sold separately\u003c\/h2\u003e\u003cp\u003eThe detector head ships without a base. Same base ecosystem as Series 3 photoelectric (B501-IV, B300-6, B200 series sounder, B224 relay \/ isolator).\u003c\/p\u003e","brand":"Gamewell-FCI","offers":[{"title":"Default Title","offer_id":51722995269925,"sku":"ASD-PL2F","price":272.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/7648\/4645\/files\/gamewell-fci-smoke-detectors-default-title-gamewell-fci-asd-pl2f-addressable-smoke-detector-35498732617952.jpg?v=1771297249"}],"url":"https:\/\/fastalarmdistribution.com\/collections\/gamewell-fci-smoke-detectors.oembed","provider":"Fast Alarm Distribution","version":"1.0","type":"link"}