{"title":"Fire-Lite Voice Systems","description":"\u003cp\u003eEmergency voice and mass-notification hardware for schools, healthcare facilities, hotels, and mid-rise buildings that need intelligible page and pre-recorded evacuation messaging. ECC-50\/100 anchors a 50W or 100W audio controller with digital message libraries, remote mic, and zone control.\u003c\/p\u003e\u003cp\u003eECC-CE4 and ECC-CE6 zone expanders, ECC-50W-25V and ECC-50W-70V auxiliary amps, ECC-RM remote microphone, and ECC-LOC local operating console pair with Fire-Lite ES-200X and ES-1000X panels.\u003c\/p\u003e","products":[{"product_id":"fire-lite-ecc-loc","title":"Fire-Lite ECC-LOC Emergency Voice Evacuation Amplifier","description":"\u003cp\u003eFire-Lite ECC-LOC local operator console for the ECC Emergency Command Center voice evacuation system.\u003c\/p\u003e\n\u003ch3\u003eCompliance\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUL 2572 listed (mass notification)\u003c\/li\u003e\n\u003cli\u003eUL 864 listed\u003c\/li\u003e\n\u003cli\u003eUL 464 listed\u003c\/li\u003e\n\u003cli\u003eNFPA 72 compatible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLocal operator console for voice message selection and zone control within the ECC system\u003c\/li\u003e\n\u003cli\u003eProvides on-site control of live page and pre-recorded message broadcasting\u003c\/li\u003e\n\u003cli\u003eDesigned for use as part of the ECC-50\/100 voice evacuation platform\u003c\/li\u003e\n\u003cli\u003eSupports NFPA 72 Chapter 24 emergency communications system requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ECC-LOC is the local operator console component of the Fire-Lite ECC Emergency Command Center voice evacuation platform. Emergency voice\/alarm communication systems (EVACS) are required by NFPA 72 in high-rise buildings, assembly occupancies, and other facilities where a tone-only alarm is insufficient for orderly evacuation. The LOC console allows a trained operator at the fire command center to select audio zones, initiate live voice pages, and override pre-recorded messages. It is designed to integrate with the ECC-50\/100 amplifier chassis and associated expander modules.\u003c\/p\u003e\n\u003cp\u003eVerify panel\/device family compatibility before ordering.\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":52004365828389,"sku":"ECC-LOC","price":1830.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/7648\/4645\/files\/fire-lite-voice-systems-default-title-fire-lite-ecc-loc-local-operator-console-34910902649056.jpg?v=1771296160"},{"product_id":"fire-lite-ecc-50w-70v","title":"Fire-Lite ECC-50W-70V Emergency Voice Evacuation Amplifier","description":"\u003cp\u003eFire-Lite ECC-50W-70V 50-watt 70-volt audio amplifier for the ECC Emergency Command Center.\u003c\/p\u003e\n\u003ch3\u003eCompliance\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUL 2572 listed (mass notification)\u003c\/li\u003e\n\u003cli\u003eUL 864 listed\u003c\/li\u003e\n\u003cli\u003eUL 1480 listed (speakers)\u003c\/li\u003e\n\u003cli\u003eNFPA 72 compatible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e50-watt amplifier output at 70 V for 25-ohm or 70-volt distributed speaker systems\u003c\/li\u003e\n\u003cli\u003eInstalls as a module within the ECC-50\/100 chassis\u003c\/li\u003e\n\u003cli\u003eSupports pre-recorded and live voice message broadcasting across assigned audio zones\u003c\/li\u003e\n\u003cli\u003eDesigned for NFPA 72 Chapter 24 emergency voice systems in commercial occupancies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 70-volt distributed audio standard is widely used in commercial fire alarm voice evacuation systems because it allows many speakers to be wired in series-parallel configurations at lower line current, reducing cable gauge requirements across large buildings. The ECC-50W-70V provides 50 watts of amplified 70 V output within the ECC chassis and is designed for zoned voice evacuation or mass notification applications where audio zones must be individually controlled. Amplifier module count and speaker tap wattages must be engineered to match the system's zone load requirements.\u003c\/p\u003e\n\u003cp\u003eVerify panel\/device family compatibility before ordering.\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":52004371824933,"sku":"ECC-50W-70V","price":550.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/7648\/4645\/files\/1069915616_lg.jpg?v=1771303598"},{"product_id":"fire-lite-ecc-xrm-70v","title":"Fire-Lite ECC-XRM-70V Emergency Voice Evacuation Amplifier","description":"\u003cp\u003eFire-Lite ECC-XRM-70V expansion amplifier module for the ECC Emergency Command Center voice evacuation system.\u003c\/p\u003e\n\u003ch3\u003eCompliance\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUL 2572 listed (mass notification)\u003c\/li\u003e\n\u003cli\u003eUL 864 listed\u003c\/li\u003e\n\u003cli\u003eUL 1480 listed (speakers)\u003c\/li\u003e\n\u003cli\u003eNFPA 72 compatible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eExpansion amplifier module at 70 V output for adding audio zones to an existing ECC system\u003c\/li\u003e\n\u003cli\u003eInstalls into the ECC chassis to increase total watt capacity and zone count\u003c\/li\u003e\n\u003cli\u003eSupports pre-recorded evacuation messages and live voice page capability\u003c\/li\u003e\n\u003cli\u003eDesigned for NFPA 72 Chapter 24 emergency communications compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ECC-XRM-70V is an expansion amplifier module that adds 70-volt audio zone capacity to an existing Fire-Lite ECC-50\/100 Emergency Command Center installation. In large or multi-zone buildings, a single base amplifier may not provide sufficient watt capacity to drive all speaker zones simultaneously; expansion modules like the ECC-XRM-70V slot into the chassis to increase output capability. Each additional module must be configured and assigned to specific audio zones during system commissioning to ensure correct routing of alarm tones and voice messages.\u003c\/p\u003e\n\u003cp\u003eVerify panel\/device family compatibility before ordering.\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":52004371857701,"sku":"ECC-XRM-70V","price":280.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/7648\/4645\/files\/fire-lite-modules-default-title-fire-lite-ecc-xrm-70v-31896799969504.jpg?v=1771296071"},{"product_id":"fire-lite-ecc-ce4-distributed-audio-zone-expander","title":"Fire-Lite ECC-CE4 Emergency Voice Evacuation Amplifier","description":"\u003cp\u003eFire-Lite ECC-CE4 four-zone audio control expander for the ECC Emergency Command Center.\u003c\/p\u003e\n\u003ch3\u003eCompliance\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUL 2572 listed (mass notification)\u003c\/li\u003e\n\u003cli\u003eUL 864 listed\u003c\/li\u003e\n\u003cli\u003eUL 464 listed\u003c\/li\u003e\n\u003cli\u003eNFPA 72 compatible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eExpands the ECC system by four additional distributed audio zones\u003c\/li\u003e\n\u003cli\u003eInstalls in the ECC chassis alongside the base amplifier modules\u003c\/li\u003e\n\u003cli\u003eEnables independent zone audio routing for zoned evacuation strategies\u003c\/li\u003e\n\u003cli\u003eSupports simultaneous alarm tone and voice message distribution per NFPA 72 Chapter 24\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ECC-CE4 is a four-zone audio control expander module for the Fire-Lite ECC Emergency Command Center platform. Emergency voice systems in large or multi-story buildings typically divide the building into audio zones — allowing operators to issue floor-specific or wing-specific evacuation messages rather than building-wide alerts. Each ECC-CE4 adds four zone outputs to the ECC chassis, extending the system's ability to drive independent speaker circuits to discrete building areas. Module count is determined during system design based on occupancy zoning requirements and NFPA 72 Chapter 24 provisions.\u003c\/p\u003e\n\u003cp\u003eVerify panel\/device family compatibility before ordering.\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":52004373430565,"sku":"ECC-CE4","price":329.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/7648\/4645\/files\/1024747694_1.jpg?v=1771303796"},{"product_id":"fire-lite-ecc-rm-remote-microphone","title":"Fire-Lite ECC-RM Emergency Voice Evacuation Amplifier","description":"\u003cp\u003eFire-Lite ECC-RM remote microphone for the ECC Emergency Command Center voice evacuation system.\u003c\/p\u003e\n\u003ch3\u003eCompliance\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUL 2572 listed (mass notification)\u003c\/li\u003e\n\u003cli\u003eUL 864 listed\u003c\/li\u003e\n\u003cli\u003eUL 1711 listed (amplifiers for fire protective signaling)\u003c\/li\u003e\n\u003cli\u003eNFPA 72 compatible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRemote microphone for live voice paging from a location separate from the main ECC console\u003c\/li\u003e\n\u003cli\u003eAllows trained personnel at a secondary station to initiate live announcements over speaker zones\u003c\/li\u003e\n\u003cli\u003eDesigned to integrate with the ECC-50\/100 chassis platform\u003c\/li\u003e\n\u003cli\u003eSupports NFPA 72 Chapter 24 requirements for distributed fire command capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn large buildings and campuses, NFPA 72 and local fire codes may require fire command capability at locations beyond the primary fire command center — such as lobby security desks, loading dock offices, or secondary stairwell entrances. The ECC-RM remote microphone extends the voice paging capability of the ECC system to a secondary station, allowing an authorized operator to initiate live announcements to selected audio zones without accessing the main console. Zone selection and microphone priority must be configured during system design and commissioning.\u003c\/p\u003e\n\u003cp\u003eVerify panel\/device family compatibility before ordering.\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":52004378083621,"sku":"ECC-RM","price":822.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/7648\/4645\/files\/FL-ECCRM_lg.jpg?v=1771304406"},{"product_id":"fire-lite-ecc-50w-25v","title":"Fire-Lite ECC-50W-25V Emergency Voice Evacuation Amplifier","description":"\u003cp\u003eFire-Lite ECC-50W-25V 50-watt 25-volt audio amplifier for the ECC Emergency Command Center.\u003c\/p\u003e\n\u003ch3\u003eCompliance\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUL 2572 listed (mass notification)\u003c\/li\u003e\n\u003cli\u003eUL 864 listed\u003c\/li\u003e\n\u003cli\u003eUL 1480 listed (speakers)\u003c\/li\u003e\n\u003cli\u003eNFPA 72 compatible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e50-watt amplifier output at 25 V for 25-volt distributed speaker systems\u003c\/li\u003e\n\u003cli\u003eInstalls as a module within the ECC-50\/100 chassis\u003c\/li\u003e\n\u003cli\u003eSupports pre-recorded evacuation messages and live voice page broadcasting across assigned zones\u003c\/li\u003e\n\u003cli\u003eDesigned for systems using 25-volt speaker wiring configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 25-volt distributed audio standard is used in smaller commercial fire alarm voice evacuation systems or in installations where 70-volt wiring is not required by design. The ECC-50W-25V provides 50 watts of amplified 25 V output within the ECC chassis and is used in place of the 70V variant when the speaker system is designed around 25-volt tap impedance values. Amplifier module selection (25 V vs. 70 V) must be consistent with the speaker tap wattage ratings selected during system design, and the total connected speaker wattage must not exceed the module's rated output capacity.\u003c\/p\u003e\n\u003cp\u003eVerify panel\/device family compatibility before ordering.\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":52004379689253,"sku":"ECC-50W-25V","price":550.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/7648\/4645\/files\/FL-ECC50W25V.jpg?v=1771303370"},{"product_id":"fire-lite-ecc-50-100","title":"Fire-Lite ECC-50\/100 Emergency Voice Evacuation Amplifier","description":"\u003cp\u003eFire-Lite ECC-50\/100 Emergency Command Center base chassis for voice evacuation systems.\u003c\/p\u003e\n\u003ch3\u003eCompliance\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUL 2572 listed (mass notification)\u003c\/li\u003e\n\u003cli\u003eUL 864 listed\u003c\/li\u003e\n\u003cli\u003eUL 1480 listed (speakers)\u003c\/li\u003e\n\u003cli\u003eNFPA 72 compatible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBase chassis supporting 50 or 100 watt amplifier configurations for voice evacuation\u003c\/li\u003e\n\u003cli\u003eAccepts ECC amplifier modules, zone expanders, remote microphone, and operator console\u003c\/li\u003e\n\u003cli\u003eSupports pre-recorded message playback and live voice paging across multiple audio zones\u003c\/li\u003e\n\u003cli\u003eDesigned for NFPA 72 Chapter 24 emergency voice\/alarm communication requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ECC-50\/100 is the base chassis of the Fire-Lite Emergency Command Center voice evacuation platform. It provides the mechanical and electrical framework into which amplifier modules (ECC-50W-25V, ECC-50W-70V), zone expanders (ECC-CE4, ECC-CE6), and operator interfaces (ECC-LOC, ECC-RM) are installed. Emergency voice\/alarm communication systems are required by NFPA 72 in high-rise buildings, large assembly occupancies, underground structures, and covered malls. The ECC system design — including amplifier wattage, zone count, and speaker circuit loads — must be engineered to meet the specific occupancy's egress and notification requirements.\u003c\/p\u003e\n\u003cp\u003eVerify panel\/device family compatibility before ordering.\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":52004390142245,"sku":"ECC-50\/100","price":2822.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/7648\/4645\/files\/fire-lite-control-panels-default-title-fire-lite-ecc-50-100-emergency-command-center-31896796791008.jpg?v=1771295803"}],"url":"https:\/\/fastalarmdistribution.com\/collections\/fire-lite-voice-systems.oembed","provider":"Fast Alarm Distribution","version":"1.0","type":"link"}